Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
The Abutment Duplication Technique: A Novel Protocol for Cementable Implant-Supported Restorations
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 30 , Issue 4
July/August 2010

Pages 415-424


The Abutment Duplication Technique: A Novel Protocol for Cementable Implant-Supported Restorations

Roberto Cocchetto, MD, DDS/Ingrid Resch, CDT/Marco Castagna, CDT/Giampaolo Vincenzi, MD, DDS/Renato Celletti, MD, DDS


PMID: 20664844
DOI: 10.11607/prd.00.0926

The purpose of this study was to present a new laboratory technique for cementable implant-supported restorations and to evaluate its efficacy in reducing chair time for both patients and clinicians, while maintaining the precision of an indirect procedure for crown fabrication. The technique consisted of the duplication of the implant portion of a working cast prepared using double-pour or plastic base die systems for single or multiple crowns. For this purpose, a flask previously intended for the production of ceramic inlays and onlays was used. Duplication was obtained using a high-precision addition silicon material and a low-shrinkage polyurethane resin. The duplicated implant abutment was used to finalize the fixed partial denture restorations after the originals were delivered to the patients. Fifty abutments were tested consecutively. The castings (19 single crowns, 31 fixed partial dentures) produced on the original abutments were seated on the duplicate abutments and evaluated by two prosthodontists and two dental technicians using a visual inspection method (laboratory microscope at 163 magnification). Forty-eight restorations were “good” (completely seated, no marginal opening) and 2 were “acceptable” (incomplete seating but amendable), with a 98% success rate. The technique presented demonstrates efficacy and predictability in reducing the number of clinical sessions for delivering precisely fitting cementable implant-supported restorations. (Int J Periodontics Restorative Dent 2010;30:415–424.)


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 